Two labels, about eight numbers, and each one answers a different question a customer might ask.

Here is how to read a window label. Most windows carry two. The NFRC label lists energy ratings: U-factor, solar heat gain coefficient (SHGC), visible transmittance (VT), and often air leakage and a condensation rating. A separate performance label shows a performance class, a performance grade and the size that was tested. Each number answers a different question, and none of them alone says whether a window is right for a job.

Windows 101 named U-factor. This lesson reads the whole label. Then you can point to the number that answers what the customer actually asked.

Marion Pulse worked in member services at the National Fenestration Rating Council when she recorded her Grit Blueprint episode in 2024. She described what the organization does:

We are a third party certification body for thermal performance for windows and doors.

Marion PulseMember Services and Engagement Manager, NFRC, in 2024 (1:08)

Third party means the manufacturer does not rate itself. NFRC’s residential program page lays out the steps: an NFRC 701 accredited laboratory does the testing and simulation, an NFRC-licensed independent inspection agency reviews the reports and makes a recommendation, and NFRC certifies the product. Learn more in her episode and on the NFRC company page.

What does each number on the NFRC label mean?

ENERGY STAR, the U.S. EPA program, explains the five NFRC categories this way. The right column is the question each one helps answer.

The NFRC energy label, one number at a time
RatingWhat it measuresWhich way is betterCustomer question
U-factorThe rate of heat transfer: how well the window insulatesLower insulates betterWill it keep the heat in on a cold night?
Solar heat gain coefficient (SHGC)The fraction of solar energy that comes throughLower lets in less solar heatWill this room bake in the afternoon sun?
Visible transmittance (VT)How much light comes throughHigher lets in more lightWill the glass look dark or tinted?
Air leakage (AL)Air passing through the joints of the windowLower leaks lessWill it feel drafty?
Condensation resistance or condensation indexHow well the window resists water build-upHigher resists moreWill the window sweat in winter?

Definitions and directions from ENERGY STAR’s page on NFRC ratings and Pella’s published definitions. What value a job needs comes from the plans, the builder or the code official.

Two notes from the sources. First, ENERGY STAR says, “ENERGY STAR qualification is based on U-factor and SHGC ratings only.” A window with the ENERGY STAR mark met criteria for those two numbers in a climate zone. It tells you nothing more about light, air or condensation. Second, ENERGY STAR also notes that NFRC “does not distinguish between ‘good’ and ‘bad’ windows, set minimum performance standards, or mandate performance levels.” The label reports. It does not judge.

Condensation resistance or condensation index?

You may see either. Pella’s technical guide lists Condensation Index (CI) as the latest standard and Condensation Resistance (CR) as the prior one, each under its own NFRC user guide. NFRC’s current residential program page names condensation index among the ratings it evaluates. An older label or brochure may still show CR. Pella’s guide says the two are calculated with different methods and their values “should not be directly compared,” so never set a CR number beside a CI number.

Whole window or just the glass?

This is where comparisons go wrong. Pella’s guide says performance “is measured at the center of glass or across the whole unit,” and defines U-factor and SHGC for either the total unit or the glazing system alone, called center-glass. NFRC says its rating system is “based on certified whole product performance.” A brochure may print a center-of-glass number, which describes the glass only. Pella’s own advice: “When comparing performance with other manufacturers, it is important to verify how the values were determined.”

The customer usually does not care about any of this. Chip Gentry, Chief Legal Officer at Quaker Windows, said it on our show:

Of course, there's all this engineering specific performance, all these numbers that we window nerds get geeked out on.

Chip GentryChief Legal Officer, Quaker Windows (22:31)

They just want to know is it gonna look good? And is it gonna perform?

Chip GentryChief Legal Officer, Quaker Windows (22:31)

That is the job at the counter: turn “is it gonna perform?” into the one number that answers the part they care about. Hear the rest in his episode.

What does the sticker itself prove?

That the unit was certified. NFRC’s FAQ is blunt: “If the product does not have a sticker on it, it is not considered a certified window (regardless of whether it is certified or not).” It also says labels cannot be emailed, faxed or sent separately from the window. If a customer took the label off, the ratings can be looked up in NFRC’s Certified Product Directory with the manufacturer and product line.

How to read a window label for strength: the performance grade

The second label is about strength, air and water, not energy. It follows the North American Fenestration Standard, also written AAMA/WDMA/CSA 101/I.S.2/A440. Andersen’s technical sheet for one of its casement windows prints this example:

One maker’s performance label, read part by part
On the labelWhat it isWhat it tells you
Class LCPerformance classThe standard has four: R, LC, CW and AW
PG40Performance gradeThe unit passed the full set of tests for that grade
Size Tested 71.5 x 71.5 in.The size of the test sampleUnits of the same design smaller than this can carry the rating
DP+40/-45Design pressure, positive and negativeStructural load only, listed on its own line

Example label from Andersen’s 100 Series product performance sheet. Other makers and certifiers lay the label out in their own way.

Andersen’s sheet draws the key line between the two numbers: “A product only achieves a ‘Performance Grade’ or ‘PG’ rating when it complies with all of the NAFS performance requirements such as ease of operation, air infiltration resistance, resistance to water penetration and resistance to forced entry, etc.” A design pressure rating “only depicts the design and structural load performance.” It also says that, based on the test, “all products of the same design that are smaller than the tested size can be labeled with this product performance rating.” So a bigger unit of the same type does not automatically carry the grade.

Which grade or design pressure a job needs is a code question. Andersen notes that “Building codes prescribe design pressure based on a variety of criteria,” including wind speed zone, building height and exposure. That number comes from the plans, the engineer or the code official.

Point to one number, then say what it doesn’t cover

In our work with window and door leaders, rating confusion comes up more than almost anything else. The numbers are real and they matter, but they are written for engineers, and customers end up buying on the one figure a salesperson happened to repeat.

So translate. Ask what the customer is worried about: cold, heat, glare, drafts, a wet sill, wind. Point to the one number on the label that speaks to that, say which way is better, and say what that number does not cover. Never call a window good or bad from its label. Show the certified rating for the exact unit, and let the job’s requirement decide.

What to ask the customer

“What are you hoping the new windows fix: cold rooms, hot rooms, drafts, fogging, or noise? Do the plans or your builder list a required U-factor, SHGC or design pressure? Is this a window on a sunny side? Are you comparing against another quote? If so, can you send me the label or the page the numbers came from?”

Checklist: before you compare two windows by their numbers

Go down this list before you compare two windows by their numbers. Any box you can’t tick is the step to go back to.

What stays product-specific

Every rating belongs to one product line in one configuration: frame, glass, spacer, grilles and size. Changing any of those can change the numbers. Label layouts differ between certifiers and makers. Energy code requirements differ by place and code edition. Use the certified rating for the exact unit and the requirement for the exact job.

What to do next

Find a new window in your yard or showroom that still has its labels. Read every number out loud and say which way is better. Then look the same unit up in NFRC’s Certified Product Directory and see if the numbers match.

The glass words behind these numbers are in Tempered, Laminated, or Insulating Glass and An Insulating Glass Unit Has More Than Two Pieces of Glass. Wind-borne debris has its own ratings: read Impact Windows and Doors. Learn more about the associations behind the standards: NFRC, FGIA and WDMA.

Disclosure: Marion Pulse is now Client Success Director at Grit Blueprint, which publishes Grit Guide. Her words here come from her 2024 Grit Blueprint Podcast interview, recorded while she was at NFRC.

Questions people ask

What is a good U-factor for a window?

Lower means the window insulates better, but what is good enough for a job depends on the climate and the energy code there. ENERGY STAR sets its own U-factor and SHGC criteria by climate zone. Get the required number from the plans, the builder or the code official, then compare it to the certified rating for the exact unit.

What does SHGC mean on a window?

Solar Heat Gain Coefficient. ENERGY STAR says it measures the fraction of solar energy transmitted and tells you how well the product blocks heat caused by sunlight. The lower the SHGC, the less solar heat the window lets in.

Is the NFRC rating for the glass or the whole window?

NFRC says its ratings are based on certified whole product performance. Some brochures also list center-of-glass numbers, which describe the glass alone, so compare total-unit numbers only with total-unit numbers. Pella’s technical guide tells readers to verify how values were determined before comparing makers.

What does PG mean on a window label?

Performance Grade. Andersen’s technical sheet says a product only achieves a PG rating when it complies with all of the North American Fenestration Standard’s performance requirements, including air, water, structural and forced-entry tests. It is printed with the performance class and the size that was tested.

My window has no NFRC sticker. Is it certified?

Not as far as the label program goes. NFRC’s FAQ says a product without the sticker is not considered a certified window, and labels cannot be sent separately. Check the NFRC Certified Product Directory or ask the manufacturer.

Episodes in this piece

Sources

  1. Independently Tested and Certified Energy Performance ENERGY STAR (U.S. EPA)
  2. Residential Certification Program and FAQ National Fenestration Rating Council
  3. 100 Series Product Performance (PG, air infiltration, label example) Andersen Windows & Doors
  4. Introduction to Performance (Thermal Performance Definitions) Pella
  5. Marion Pulse on Confidence, Patience and Finding Your Place in Fenestration (December 2024) Grit Guide
  6. Build Loyalty Like a 76-Year Family Business: Chip Gentry, Chief Legal Officer at Quaker Windows Grit Guide
  7. The NFRC Label (Efficient Windows, published by NFRC) National Fenestration Rating Council

Also named on this page

People and companies mentioned above, each with a page on Grit Guide.