NFRC
National Fenestration Rating Council: the nonprofit that certifies and labels the energy performance of windows, doors and skylights.
- Category
- Associations
- What They Sell
- Energy Ratings & Certification
- Headquarters
- Greenbelt, MD
- Founded
- 1989
- Ownership
- Nonprofit, 501(c)(3)
- Website
- nfrc.org
QuickAnswer
The National Fenestration Rating Council (NFRC) is a 501(c)(3) nonprofit in Greenbelt, Maryland that certifies and labels the energy performance of windows, doors and skylights. Formed in 1989, NFRC certifies the U‑factor, Solar Heat Gain Coefficient, Visible Transmittance, Air Leakage and Condensation Resistance ratings on its label, and lists certified products in its Certified Products Directory.
Watch and read
Episodes, clips, articles and lessons on Grit Guide that feature NFRC.
Episode 1
Marion Pulse on Confidence, Patience and Finding Your Place in Fenestration
A year of learning in a safe space at the corporate office made the jump into window and door sales a lot easier, though plenty of reps succeed learning on the spot.
Lessons 10
Double Pane vs. Triple Pane Windows: What Changes and What to Ask
Tempered, Laminated, or Insulating Glass: These Terms Describe Different Things
Customer Follow-Up Scripts You Can Copy: After a Quote, a Delivery and a Problem
How to Keep a Wins List and Use It at Review Time
How to Prepare for a First Builder Meeting
The Window Label Has Several Numbers. Which One Answers the Question?
Who Is NFRC?
The National Fenestration Rating Council is an independent 501(c)(3) nonprofit certification body for the energy performance of windows, doors and skylights. NFRC says it has more than 35 years of expertise, and its offices are at 6305 Ivy Lane in Greenbelt, Maryland. NFRC traces its start to 1989, when about two dozen industry stakeholders met at an ASHRAE meeting in Vancouver and voted to form a national organization for a uniform fenestration energy rating system.
The NFRC label is the part a dealer or builder sees. On a window it shows U‑factor, which measures how well a product keeps heat from escaping a room, on a range of 0.20 to 1.20 where lower is better. It also shows Solar Heat Gain Coefficient, where low numbers resist solar heat, Visible Transmittance, which measures daylight, plus Air Leakage and Condensation Resistance. Door labels show U‑factor and SHGC.
Certified products can be looked up in the NFRC Certified Products Directory. NFRC runs residential and commercial certification, with project‑specific label certificates and the CMAST tool for commercial buildings, and opens its documents for public review under the ANSI process. NFRC is also the official certification body for ENERGY STAR windows, doors and skylights.
Why They’re Listed
The U‑factor and solar heat gain numbers on a window or door label are NFRC certified ratings, and NFRC’s Certified Products Directory can be searched to check them.
Product Lines
-
NFRC Label Certified ratings for U‑factor, SHGC, Visible Transmittance, Air Leakage and Condensation Resistance on windows, and U‑factor and SHGC on doors.
-
Certified Products Directory An online search of NFRC‑certified products and their ratings.
-
Residential Certification Rating and labeling of residential windows, doors and skylights.
-
Commercial Certification Project‑specific label certificates for commercial buildings and the CMAST commercial tool.
-
Documents And Standards NFRC documents, opened for public review and comment under the ANSI process.
Key Features
- Independent Nonprofit. NFRC calls itself an independent 501(c)(3) certification body.
- Searchable Directory. The Certified Products Directory can be searched to confirm a current certification.
- Comparable Ratings. NFRC says its label helps buyers compare windows, doors and skylights on the same rating categories.
Lower U-Factor, Less Heat Lost
Read The Label
U‑factor on an NFRC window label runs from 0.20 to 1.20, and lower means the product keeps more heat in. SHGC runs from 0 to 1, and lower means it blocks more solar heat. Visible Transmittance also runs from 0 to 1, and higher means more daylight.
By The Numbers
- Founded
- 1989
- Years of expertise, per NFRC
- 35+
- U-factor range on the window label
- 0.20 to 1.20
When To Choose NFRC
- You need certified U‑factor and SHGC numbers for a submittal. They are printed on the NFRC label.
- A customer wants to compare two brands. The NFRC label is built to help compare windows, doors and skylights.
- You bid commercial work. NFRC has project‑specific label certificates and the CMAST tool.
- You want to confirm a rating. The Certified Products Directory can be searched online.
Questions To Ask Your Rep
- What are this unit’s certified U‑factor and SHGC, and does it meet my climate zone?
- Is this exact configuration listed in the NFRC Certified Products Directory?
- Does the rating change with the glass package I am ordering?
- Will the label stay on the unit through the inspection?
- For commercial work, who handles the NFRC label certificate?
Partner Programs
-
Certified Products Directory
Search NFRC‑certified windows, doors and skylights by maker and product.
-
CMAST
NFRC’s commercial tool for rating commercial fenestration projects.
Frequently Asked Questions
What is NFRC?
The National Fenestration Rating Council is an independent 501(c)(3) nonprofit that certifies the energy performance of windows, doors and skylights. It is based in Greenbelt, Maryland.
What does U-factor mean on a window label?
U‑factor measures how well a product keeps heat from escaping a room. On the NFRC window label it runs from 0.20 to 1.20, and a lower number is better.
What is SHGC?
Solar Heat Gain Coefficient measures how much solar heat a product allows in. It runs from 0 to 1, and low numbers resist solar heat while high numbers allow it in.
What ratings are on the NFRC label?
The NFRC window label shows U‑factor, Solar Heat Gain Coefficient, Visible Transmittance, Air Leakage and Condensation Resistance. The door label shows U‑factor and SHGC.
How do I check a product’s NFRC rating?
Search the NFRC Certified Products Directory at search.nfrc.org. A search by CPD number returns products with a current certification.
When was NFRC founded?
NFRC dates to 1989, when about two dozen industry stakeholders at an ASHRAE meeting in Vancouver decided to form a national organization to run a uniform fenestration energy rating system.
GritConnected
The people, companies and topics that come up most here on Grit Guide.
Top people
-
Expert card Tap to open
-
Expert card Tap to open
Barry Williams Window Division Manager, Tucker Door and Trim Grit Guide Expert Watch their episode with Barry Williams -
Expert card Tap to open
Chip Gentry Chief Legal Officer, Quaker Windows & Doors Grit Guide Expert Watch their episode with Chip Gentry -
Expert card Tap to open
Eric Knox Director of LBM Sales, Do it Best Group Grit Guide Expert Watch their episode with Eric Knox
-
Sarah Krey Merchandise Manager, Do it Best Group Grit Guide Contributor Watch their episode with Sarah Krey
-
Chris Kotlowski Runs production for the window department, Tucker Door and Trim Grit Guide Contributor Watch their Behind the Build with Chris Kotlowski
-
Nick Pesl Regional Sales Manager, Kolbe Windows & Doors Grit Guide Contributor Watch their episode with Nick Pesl
Top companies
Also named on this page
Companies and people this profile mentions, each with a page on Grit Guide.
Is this your company?
Claim your listing, add your story and photos, or talk to us about a feature. Featured placement is paid and always labeled.
Disclosures
Grit Guide listings are editorial selections. Featured and sponsored placements are paid and always labeled, and paid placement never changes what we say about a company. Company information comes from public sources and manufacturer materials, is current to the best of our knowledge as of July 2026, and can change without notice; confirm product details, availability, pricing, and warranty terms directly with each company before you buy. Editorial opinions, including “Why They’re Listed” and comparisons, are our own, are provided for general information only, and do not imply endorsement by or affiliation with any company named unless expressly stated. All company names, logos, and trademarks are the property of their respective owners and are used for identification purposes only; owners may request updates or removal at any time. Spot an error? Claim the listing above and we will correct it fast.









