Two panes, a spacer, a drying agent, two seals and a gas. When one of them fails, the glass fogs.

An insulating glass unit, or IGU, is the sealed glass package in most windows and many doors. Customers call it double pane. It has more parts than the name suggests: two or more panes, a spacer that holds them apart at the edges, a drying agent inside the spacer, a primary seal and a secondary seal, the air or gas in the space between, and often a coating on one or more glass surfaces. When a seal lets moisture in faster than the drying agent can hold it, the unit fogs between the panes.

Tempered, Laminated, or Insulating Glass introduced the IGU. This lesson takes it apart, so you can name each piece, tell a failed unit from ordinary condensation, and record the right details before anyone orders a replacement.

How an insulating glass unit is made

At Tucker Door & Trim in Monroe, Georgia, once the glass for a window is cut, it goes through one room. Chris Kotlowski, who runs production for the window department, walked us through it:

When you get the glass cut, it goes through our green room where we insulate our glass, and when it comes out the other end it gets distributed through other departments.

Chris KotlowskiWindow production, Tucker Door & Trim (2:20)

In that room, the washed glass gets its spacer and seal system, goes through a heated press to the overall thickness the order calls for, and then gets filled. Chris described the last step:

He'll grab the glass and put air in it, or argon, depending on what the customer wants.

Chris KotlowskiWindow production, Tucker Door & Trim (5:45)

He also explained why the room is held at 73 degrees all year: the sealing material needs it. Watch the line in How Windows Are Made at Tucker Door & Trim. At GlassBuild in Orlando, we filmed a spacer line. It roll-forms flat metal coil into a U-shaped channel and cuts each piece to length. The last step, which applies sealant and desiccant to the spacer, was not on the show floor, so it was explained rather than shown. See it in How High-Performance Window Spacers Are Made.

The parts of an insulating glass unit

Guardian Glass publishes a plain guide to the makeup of an IGU. Here are its parts, with what each one does.

What is inside an insulating glass unit
PartWhat it isWhat it does
GlassTwo or more lites. May be annealed, heat-treated, laminated or coatedLight, view and, with a low-E coating, solar control and insulation
Air spaceThe sealed cavity between the panesSlows heat moving across the unit. May hold air or a gas such as argon
SpacerA metal or non-metal part that separates the panes at the edgeHolds the gap, contains the desiccant and adds strength to the unit
DesiccantA drying agent inside the spacerKeeps the space dry by soaking up moisture that gets in
Primary sealMaterial along the spacer’s shoulder, usually staying pliableA barrier to gas and water vapor
Secondary sealAn elastic bond between the glass and the spacerHolds the unit together and protects the primary seal

From Guardian Glass, Expert Series: Insulating Glass (2020). Materials and designs differ by maker.

Warm edge spacer
A spacer made of lower-conductance material, such as stainless steel or a non-metal, instead of a highly conductive one such as aluminum. It slows heat moving through the edge of the unit.

Gas is part of the package too. Guardian notes that argon is heavier than air and slows the loop of moving air inside the unit. It also says it is natural for these gases to diffuse through the edge seal over time, and that the remaining gas keeps insulating.

How glass surfaces are numbered

Coatings and markings are placed on a specific surface, and the industry counts them one way. Guardian puts it simply: “IGU glass surface numbers are identified by counting from exterior (surface #1) to interior.” In a double-pane unit that gives four surfaces: #1 outside, #2 and #3 facing the space between the panes, #4 facing the room. A triple-pane unit has six.

Where the coating goes depends on the product. Cardinal’s insulating glass guide notes that its low-E coatings “are placed on #2 surface unless otherwise indicated,” and lists products with a coating on #3 or #4. When you read a glass description or order replacement glass, write the surface number next to the coating name.

Why does an insulating glass unit fog?

Guardian describes the life of a unit plainly: “From the time of fabrication until IGU failure, moisture will slowly penetrate the seal. Desiccant adsorbs this moisture until it reaches saturation. At this point moisture will begin to accumulate in the IGU and fogging between the panes may occur.” That is a seal failure.

Some failures have a cause you can help avoid. Cardinal’s technical bulletin on sealant compatibility warns that some wood preservatives, glazing sealants, setting blocks, glazing boots and wood stains or varnishes can migrate into the seals and break them down. Its list of results includes moisture between the panes, lower argon and “chemical fogging of the airspace.” Finishing products touching the edge of the glass are not always harmless. Point customers to the window maker’s finishing instructions.

First, which surface is wet?

  • Room side (surface #4 on a double-pane unit): condensation from humid indoor air on cold glass. Therma-Tru’s glossary calls condensation “a natural occurrence in the home.” Not a seal failure.
  • Outside surface (#1): outdoor condensation. Not a seal failure.
  • Between the panes: fog, droplets or a film you cannot wipe from either side. This points to the unit itself.

Ask the customer to wipe each side. If the haze stays, it is inside the unit. Reading the condensation number on the label is covered in The Window Label Has Several Numbers.

Write down the glass before anyone reorders it

Wrong-sized glass is a costly mistake with a simple fix. Use a checklist, and have a second person read a high-stakes order before it goes out: whoever wrote the order has looked at it too long to see what is missing.

So record the glass before anyone reorders it. Brand and line first. Then the build-up, the coating and its surface, the spacer, any safety glass marking and the size the maker asks for. Let the manufacturer confirm the replacement before anything is ordered.

What to record before you call support

Checklist: A fogged or broken glass unit

Tick these off as you go. Any box you can’t tick is the step to go back to.

What to ask the customer

“If you wipe the glass inside and out, is the haze still there? Can you send me a photo of the whole window and a close one of each corner? Is there a name or a code printed on the metal strip between the panes or etched in a corner? Do you know when the windows went in? Has anything been stained, painted or caulked near the glass lately?”

What stays product-specific

Glass thicknesses, spacer type, seal materials, gas fill, coating type and surface, unit thickness, markings and replacement options belong to the window maker and its glass supplier. So does any warranty on the seal. Certification programs such as the Insulating Glass Certification Council’s verify units against ASTM standards, as Guardian’s guide notes, but the unit in a customer’s window is identified by its maker.

What to do next

Find a cut sample or a corner section of an insulating glass unit in your showroom. Point to the spacer, the seals and the space between the panes, and count the surfaces from the outside. Then find the glass guide for the window line your store sells most and look up which surface its low-E coating is on.

The words on the window label are next in The Window Label Has Several Numbers. Learn more from Tucker Door & Trim, Cardinal Glass and Vitro Architectural Glass. New words are in the Building Industry Glossary.

Questions people ask

Why is there fog between the panes of my window?

Usually because the unit’s seal has failed. Guardian Glass explains that moisture slowly gets through the seal over the life of the unit, the drying agent in the spacer absorbs it until it is full, and then moisture builds up and the glass fogs between the panes. That is called a seal failure.

Is condensation on the inside of the window a seal failure?

No. Water on the room-side surface is condensation from humid indoor air meeting cold glass, and water on the outside surface is outdoor condensation. Only fog or moisture between the panes points to the unit’s seal. Ask which surface before anything else.

Can you replace just the glass in a window?

Sometimes. Whether the insulating glass unit can be replaced on its own depends on the product, and the manufacturer decides what replacement it supplies. The new unit has to match the old one’s size, thickness, glass types, coating, spacer and any safety glass marking. Get those details and the window’s brand and line before you quote.

What surface is the low-E coating on?

Glass surfaces are numbered from the outside in, starting with surface #1. Cardinal’s glass guide says its coatings are placed on the #2 surface unless otherwise indicated, and it lists one coating on #3 and a room-side coating on #4. So the surface is product-specific: read it from the glass description.

What does warm edge spacer mean?

A spacer made of a lower-conductance material, such as stainless steel or a non-metal, instead of a highly conductive one like aluminum. Guardian Glass says warm edge spacers slow heat moving through the edge of the unit. The term covers many designs, so ask which spacer a unit has.

Episodes in this piece

Sources

  1. Expert Series: Insulating Glass (2020) Guardian Glass
  2. Technical Service Bulletin IG15: Compatibility with Insulating Glass Sealants Cardinal Glass Industries
  3. Insulating Glass brochure Cardinal Glass Industries
  4. Glossary of Common Door Terms (Desiccant, Insulating Glass) Therma-Tru Doors
  5. How Windows Are Made: Glass, Vinyl, PVC, and Wood | Behind The Build at Tucker Door & Trim, Part 2 Grit Guide

Also named on this page

People and companies mentioned above, each with a page on Grit Guide.